Home > Defibrillator Monitor > Veterinary Portable Biphasic Defibrillator

  • Veterinary Portable Biphasic Defibrillator
    • Veterinary Portable Biphasic Defibrillator
    • Veterinary Portable Biphasic Defibrillator
    • Veterinary Portable Biphasic Defibrillator
    • Veterinary Portable Biphasic Defibrillator
  • Veterinary Portable Biphasic Defibrillator
    Shinova
    DM8D-II
    Defibrillator Monitor
    Get Latest Price!
    T/T, L/C, Paypal, Cash, Other

Specifications

DEFIBRILLATOR

 (1)Defibrillator type: Manual, Synchronized, Asynchronized,    

 (2)Out put waveform: Biphasic technology                                                                            

 (3)Energy accuracy: +1%

 (4)Energy selection: 0, 3, 5, 7, 10, 20,30, 50,100,200,300,360 joule(nominal at a resistance of 50)

 (5)Charging time: Maximum 8 seconds to 360 Joules

 (6)Standard Adult/Pediatric Paddles: Reusable external adult paddles(pediatric paddles integrated)            

Power requirements

(a)AC Power supply: 110V, 60 Hz /220V,50 Hz  

(b)Vehicle Voltage: DC 12V

 

Internal Battery Backup

(1)Battery type: Rechargeable lead-acid battery

(2)Charging time: Time-Minimum of 4 hours for full charging    

(3)Battery charging: During AC Power Supply operation of the device.

(4)Charging /Low Battery Indication: Red LED                

(5)Battery Capacity: 100% of the battery will provide 120 mins of monitoring; and 30 discharges at 360 joules.

Display

-LED Dimensions: 7”diagonal {155mm*88mm} which is easily read from a distance.

-Type: High resolution true-color graphic LED

-Resolution: 480X234

- Provide cardioversion facilities with waveform annotated on the screen

- Display 4 seconds of ECG at 25mm/sec, ECG selectable from leads I, II, III when used with a 3-lead cable, and I, II, III aVL, aVR, aVF and V when used with a 5-lead cable.

- Display prompts, waveform settings, battery status, event summary and fault codes. Energy selected is displayed by push button under the screen.

ECG

ECG lead: I, II, III, AVR, AVL, AVF, V1V6, GND
S-T segment analysis: -2.0
2.0mv
Arrhythmia analysis: yes
Protection: With stand 4000vAc/50Hz voltage in isolation and work against electrosurgical knife and defibrillation

Respiration

Measurement method: Thoracic impedance

Standard parameter & configuration

 ECG/ RESP/DEFIBRILLATOR

 

-Provide audible and visual alarms for heart rate violations, VF and VT.
-Provide a strip printer which annotates waveforms, events, time code

Copyright © 2005-2018 SHINOVA. All rights reserved.