Home > Syringe Pump > Syringe pump

  • Syringe pump
    • Syringe pump
  • Syringe pump
    Shinova
    Syli 502V
    Syringe Pump
    Get Latest Price!
    T/T, L/C, Paypal, Cash, Other

Descriptions

Friendliness

 3” large LCD screen allows infusion status to be viewed easily

 User friendly keypad design

 Embedded handle allows for easy transportation

 Intuitive programming procedure with quick guidance on screen

 

Safety

 High accuracy: ±2%, satisfying neonatal use

 Fast start, Anti-bolus, Drug name display, History record, Last therapy parameter memory

 IP34 dust and water protection

 

Connectivity

 Nurse call/ RS 232/ DC input

Specifications

Specifications and functions

 

Dimension

360 x 145 x 123mm

Syringe size

5, 10, 20, 30, 50/60ml

Infusion mode

Rate mode, Time mode, Body weight mode

 

Flow rate range

5ml syringe: (0.1~150)ml/h;

10ml syringe: (0.1~300)ml/h;

20ml syringe: (0.1~600)ml/h;

30ml syringe: (0.1~900)ml/h;

50ml/60ml syringe: (0.1~1500)ml/h

Accumulated volume

0.1~9999 ml

VTBI

0.1~999.9 ml, increment is 0.1 ml; 1000-9999ml, increment is 1ml

Increment

0.1~999.9 ml/h, increment is 0.1 ml/h; 1000~1500 ml/h, increment is 1 ml/h

Accuracy

≤ ±2%

KVO rate

0.1-5.0 ml/h, adjustable, increment is 0.1ml/h

Bolus rate

0.10-1500ml/h

Purge rate

150-800ml/h

 

Occlusion

Low 300±125 mmHg (40kPa);

Medium 525±125 mmHg (70kPa);

High 900±180 mmHg (120 kPa)

Screen

3.0'' LCD monochrome screen, 240 x 128 pixels

Titration

Yes, increment is 0.1ml/h

Keypad lock

Yes

Pause

Yes

Automatic recognition of syringe size

Yes

Self-test system

Yes

Last therapy parameter memory

Yes

Drug library

200 drugs

History record

1500 events

Weight

< 1.95kg (not including clamp)

Handle

Embedded handle

Mounting type

Standard: Vertical Pole

Alarm Volume

1-8 levels selectable

Preset syringe brand

Include B-D Luer-Lok Tip,B.Braun OPS,Terumo SS; Local brand configuration supported

Language

7, Chinese, English, Spanish, French, Russian, Turkish, Portuguese

Alarm

 

 

V TBI done, V TBI near done, KVO finish, syringe empty, syringe near empty, syringe not installed, syringe disengaged, occlusion, system error, system abnormal, batter y low, batter y empty, reminder, AC power disconnection, standby time expired

Safety Requirement

 

AC power

100-240V (50/60Hz, 0.4-0.14A)

DC power

10-16V (2.0-1.25A)

Battery type

Lithium

Battery operation time

>6 hours@5ml/h

Charging time

< 5 hours@100%

Classification

CF, Class I

IP Grade

IP 34

Temperature

5~40ºC for operating, -20~60ºC for storage

Humidity

15~95% for operating, 10~95% for storage

Air pressure

57~106kPa for operating, 50~106kPa for storage

Inter face

 

Data interface

Supported, RS232

Nurse Call

Supported

DC input

Supported